CVE-2026-89712

CVE-2026-89712: critical vulnerability affecting the affected product. Check CVSS, KEV status, business impact and recommended administrator actions.
CVE-2026-89712CVSS 9.8Linux

CVE-2026-89712

CVE-2026-89712: critical vulnerability affecting the affected product. Check CVSS, KEV status, business impact and recommended administrator actions.

CVSS
9.8 CRITICAL
EPSS
52.87%
Known exploited
not in KEV
Product
-

What is known

In the Linux kernel, the following vulnerability has been resolved: NFSD: restart ssc_expire_umount walk after dropping nfsd_ssc_lock nfsd4_ssc_expire_umount() walks nn->nfsd_ssc_mount_list with list_for_each_entry_safe(ni, tmp, ...). For each expired entry it sets nsui_busy = true, drops nfsd_ssc_lock to run mntput() on the source vfsmount, then reacquires the lock to list_del + kfree the entry and continue iterating via the macro's saved tmp pointer. The nsui_busy flag protects the current ni from concurrent nfsd4_ssc_setup_dul() finders during the lock-drop window, but it does not pin tmp. Another nfsd RPC thread that fails its source- server mount and reaches nfsd4_ssc_cancel_dul() will, during that same window, take nfsd_ssc_lock, list_del + kfree its own ssc_umount item, and release the lock. If that item is the saved tmp of the expire walk, the next iteration dereferences a freed nfsd4_ssc_umount_item. Restart the walk from the head after the mntput() unlock window so no saved next pointer survives the lock-drop. The list is bounded by the number of active inter-server source mounts (typically small) and the expire delayed-work runs periodically rather than per-IO, so the restart is cheap.

Business impact

Successful exploitation of CVE-2026-89712, a critical vulnerability (CVSS 9.8) affecting the affected product, may affect the confidentiality, integrity or availability of the vulnerable environment. The exact impact depends on the installed version, exposed interfaces and deployment configuration.

Recommended administrator action

Confirm whether the affected product is present and compare installed versions with the vendor advisory and NVD record. Apply the vendor patch or documented mitigation; until remediation is complete, reduce exposure of affected interfaces, review relevant logs and monitor for indicators of exploitation. DataHouse can support version verification, managed patching, network exposure reduction, log review and backup validation for dedicated, cloud and colocated environments.

Sources

Security newsletter

Get new CVE alerts before they become an incident

We send selected infrastructure threats in English, with practical notes for DataHouse environments.

  • DataHouse: server administration and secure cloud
  • Hostilla.pl: hosting and mail services
  • SecDNS.pl: free DNS security layer