CVE-2026-89538
CVE-2026-89538: critical vulnerability affecting the affected product. Check CVSS, KEV status, business impact and recommended administrator actions.
- CVSS
- 9.8 CRITICAL
- EPSS
- 52.86%
- Known exploited
- not in KEV
- Product
- -
What is known
In the Linux kernel, the following vulnerability has been resolved: SUNRPC: Reject krb5 v2 wrap tokens with oversized ec field gss_krb5_unwrap_v2() sets buf->len to a logical length, which can be much smaller than head[0].iov_len (the allocated receive-page capacity). It then calls xdr_buf_trim() with a trim length derived from the 16-bit "extra count" (ec) field in the Kerberos v2 token header. The ec field is authenticated by the post-decrypt memcmp() against the encrypted header copy, so a randomly-mutated value is rejected. However, any peer holding a valid GSS context can legitimately encrypt a token whose ec exceeds the plaintext length. Per RFC 4121, such a token is structurally malformed. Although xdr_buf_trim() now clamps the buf->len subtraction to avoid unsigned underflow, the buffer is still left in a semantically invalid state (zero length, inconsistent iov lengths) when ec is oversized. Reject these tokens before calling xdr_buf_trim(), giving callers a well-defined GSS_S_DEFECTIVE_TOKEN error and keeping the xdr_buf internally consistent. The wrapped blob begins at a nonzero offset -- both callers pass len as offset + opaque_len -- so buf->len still counts the offset bytes that precede the blob. Compare the trim length against the remaining wrapped segment, buf->len - offset, rather than the whole buffer; comparing against buf->len alone leaves an offset-wide window in which an oversized ec passes the test and xdr_buf_trim() cuts into the bytes ahead of the blob.
Business impact
Successful exploitation of CVE-2026-89538, a critical vulnerability (CVSS 9.8) affecting the affected product, may affect the confidentiality, integrity or availability of the vulnerable environment. The exact impact depends on the installed version, exposed interfaces and deployment configuration.
Recommended administrator action
Confirm whether the affected product is present and compare installed versions with the vendor advisory and NVD record. Apply the vendor patch or documented mitigation; until remediation is complete, reduce exposure of affected interfaces, review relevant logs and monitor for indicators of exploitation. DataHouse can support version verification, managed patching, network exposure reduction, log review and backup validation for dedicated, cloud and colocated environments.