CVE-2026-74384

CVE-2026-74384: critical vulnerability affecting the affected product. Check CVSS, KEV status, business impact and recommended administrator actions.
CVE-2026-74384CVSS 9.8Linux

CVE-2026-74384

CVE-2026-74384: critical vulnerability affecting the affected product. Check CVSS, KEV status, business impact and recommended administrator actions.

CVSS
9.8 CRITICAL
EPSS
42.8%
Known exploited
not in KEV
Product
-

What is known

In the Linux kernel, the following vulnerability has been resolved: nvme-multipath: fix flex array size in struct nvme_ns_head struct nvme_ns_head contains a flexible array member, current_path[], which is indexed using the NUMA node ID: head->current_path[numa_node_id()] The structure is currently allocated as: size = sizeof(struct nvme_ns_head) + (num_possible_nodes() * sizeof(struct nvme_ns *)); head = kzalloc(size, GFP_KERNEL); This allocation assumes that NUMA node IDs are sequential and densely packed from 0 .. num_possible_nodes() - 1. While this assumption holds on many systems, it is not always true on some architectures such as powerpc. On some powerpc systems, NUMA node IDs can be sparse. For example: NUMA: NUMA node(s): 6 NUMA node0 CPU(s): 80-159 NUMA node8 CPU(s): 0-79 NUMA node252 CPU(s): NUMA node253 CPU(s): NUMA node254 CPU(s): NUMA node255 CPU(s): That is, the possible/online NUMA node IDs are: 0, 8, 252, 253, 254, 255 In this case: num_possible_nodes() = 6 So memory is allocated for only 6 entries in current_path[]. However, the array is later indexed using the actual NUMA node ID. As a result, accesses such as: head->current_path[8] or head->current_path[252] goes out of bounds, leading to the following KASAN splat: ================================================================== BUG: KASAN: slab-out-of-bounds in nvme_mpath_revalidate_paths+0x22c/0x290 [nvme_core] Write of size 8 at addr c00020003bda35b8 by task kworker/u641:2/1997 CPU: 1 UID: 0 PID: 1997 Comm: kworker/u641:2 Not tainted 7.1.0-rc5-dirty #14 PREEMPT(lazy) Hardware name: 8335-GTH POWER9 0x4e1202 opal:skiboot-v6.5.3-35-g1851b2a06 PowerNV Workqueue: async async_run_entry_fn Call Trace: [c000200037fa7510] [c0000000021c23d4] dump_stack_lvl+0x88/0xdc (unreliable) [c000200037fa7540] [c0000000009fda90] print_report+0x22c/0x67c [c000200037fa7630] [c0000000009fd508] kasan_report+0x108/0x220 [c000200037fa7740] [c0000000009fff48] __asan_store8+0xe8/0x120 [c000200037fa7760] [c008000018e76474] nvme_mpath_revalidate_paths+0x22c/0x290 [nvme_core] [c000200037fa7800] [c008000018e6556c] nvme_update_ns_info+0x4a4/0x5e0 [nvme_core] [c000200037fa7a50] [c008000018e66270] nvme_alloc_ns+0x6d8/0x1a70 [nvme_core] [c000200037fa7c20] [c008000018e679fc] nvme_scan_ns+0x3f4/0x630 [nvme_core] [c000200037fa7d10] [c00000000031f22c] async_run_entry_fn+0x9c/0x3a0 [c000200037fa7db0] [c0000000002fa544] process_one_work+0x414/0xa10 [c000200037fa7ec0] [c0000000002fbf00] worker_thread+0x320/0x640 [c000200037fa7f80] [c00000000030d0f8] kthread+0x278/0x290 [c000200037fa7fe0] [c00000000000ded8] start_kernel_thread+0x14/0x18 Allocated by task 1997 on cpu 1 at 35.928317s: The buggy address belongs to the object at c00020003bda3000 which belongs to the cache kmalloc-rnd-15-2k of size 2048 The buggy address is located 16 bytes to the right of allocated 1448-byte region [c00020003bda3000, c00020003bda35a8) The buggy address belongs to the physical page: Memory state around the buggy address: c00020003bda3480: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 c00020003bda3500: 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 >c00020003bda3580: 00 00 00 00 00 fc fc fc fc fc fc fc fc fc fc fc ^ c00020003bda3600: fc fc fc fc fc fc fc fc fc fc fc fc fc fc fc fc c00020003bda3680: fc fc fc fc fc fc fc fc fc fc fc fc fc fc fc fc ================================================================== Fix this by allocating the flexible array using nr_node_ids instead of num_possible_nodes(). Since nr_node_ids represents the maximum possible NUMA node IDs, indexing current_path[] using numa_node_id() becomes safe even on systems with sparse node IDs.

Business impact

Successful exploitation of CVE-2026-74384, a critical vulnerability (CVSS 9.8) affecting the affected product, may affect the confidentiality, integrity or availability of the vulnerable environment. The exact impact depends on the installed version, exposed interfaces and deployment configuration.

Recommended administrator action

Confirm whether the affected product is present and compare installed versions with the vendor advisory and NVD record. Apply the vendor patch or documented mitigation; until remediation is complete, reduce exposure of affected interfaces, review relevant logs and monitor for indicators of exploitation. DataHouse can support version verification, managed patching, network exposure reduction, log review and backup validation for dedicated, cloud and colocated environments.

Sources

Security newsletter

Get new CVE alerts before they become an incident

We send selected infrastructure threats in English, with practical notes for DataHouse environments.

  • DataHouse: server administration and secure cloud
  • Hostilla.pl: hosting and mail services
  • SecDNS.pl: free DNS security layer