CVE-2024-58060: linux kernel vulnerability

CVE-2024-58060: high vulnerability affecting linux kernel. Check CVSS, KEV status, business impact and recommended administrator actions.
CVE-2024-58060CVSS 7.8Linux

CVE-2024-58060: linux kernel vulnerability

CVE-2024-58060: high vulnerability affecting linux kernel. Check CVSS, KEV status, business impact and recommended administrator actions.

CVSS
7.8 HIGH
EPSS
10.48%
Known exploited
not in KEV
Product
linux kernel

What is known

In the Linux kernel, the following vulnerability has been resolved: bpf: Reject struct_ops registration that uses module ptr and the module btf_id is missing There is a UAF report in the bpf_struct_ops when CONFIG_MODULES=n. In particular, the report is on tcp_congestion_ops that has a "struct module *owner" member. For struct_ops that has a "struct module *owner" member, it can be extended either by the regular kernel module or by the bpf_struct_ops. bpf_try_module_get() will be used to do the refcounting and different refcount is done based on the owner pointer. When CONFIG_MODULES=n, the btf_id of the "struct module" is missing: WARN: resolve_btfids: unresolved symbol module Thus, the bpf_try_module_get() cannot do the correct refcounting. Not all subsystem's struct_ops requires the "struct module *owner" member. e.g. the recent sched_ext_ops. This patch is to disable bpf_struct_ops registration if the struct_ops has the "struct module *" member and the "struct module" btf_id is missing. The btf_type_is_fwd() helper is moved to the btf.h header file for this test. This has happened since the beginning of bpf_struct_ops which has gone through many changes. The Fixes tag is set to a recent commit that this patch can apply cleanly. Considering CONFIG_MODULES=n is not common and the age of the issue, targeting for bpf-next also.

Business impact

Successful exploitation of CVE-2024-58060, a high vulnerability (CVSS 7.8) affecting linux kernel, may affect the confidentiality, integrity or availability of the vulnerable environment. The exact impact depends on the installed version, exposed interfaces and deployment configuration.

Recommended administrator action

Confirm whether linux kernel is present and compare installed versions with the vendor advisory and NVD record. Apply the vendor patch or documented mitigation; until remediation is complete, reduce exposure of affected interfaces, review relevant logs and monitor for indicators of exploitation. DataHouse can support version verification, managed patching, network exposure reduction, log review and backup validation for dedicated, cloud and colocated environments.