CVE-2026-64540
CVE-2026-64540: reported vulnerability affecting the affected product. Check CVSS, KEV status, business impact and recommended administrator actions.
- CVSS
- -
- EPSS
- -
- Known exploited
- not in KEV
- Product
- -
What is known
In the Linux kernel, the following vulnerability has been resolved: usbnet: gl620a: fix out-of-bounds read in genelink_rx_fixup() genelink_rx_fixup() splits an aggregated RX frame into its individual packets, using a per-packet length taken from device-supplied data. That length is only bounded by GL_MAX_PACKET_LEN (1514); it is never compared against how many bytes were actually received. A malicious GeneLink (GL620A) device can therefore send a short URB whose header claims packet_count > 1 and a first packet of up to 1514 bytes. skb_put_data(gl_skb, packet->packet_data, size); then copies past the end of the receive buffer and hands the adjacent slab contents up the network stack, an out-of-bounds read that leaks kernel heap. No privilege is required: the path runs in the usbnet RX softirq as soon as the interface is up. BUG: KASAN: slab-out-of-bounds in genelink_rx_fixup (drivers/net/usb/gl620a.c:112) Read of size 1514 at addr ffff888011309708 by task ksoftirqd/0/14 Call Trace: ... __asan_memcpy (mm/kasan/shadow.c:105) genelink_rx_fixup (include/linux/skbuff.h:2814 drivers/net/usb/gl620a.c:112) usbnet_bh (drivers/net/usb/usbnet.c:572 drivers/net/usb/usbnet.c:1589) process_one_work (kernel/workqueue.c:3322) bh_worker (kernel/workqueue.c:3405) tasklet_action (kernel/softirq.c:965) handle_softirqs (kernel/softirq.c:622) run_ksoftirqd (kernel/softirq.c:1076) ... skb_pull() already verifies that the requested length fits the buffer and returns NULL otherwise. Move it ahead of the copy and check its result, so a packet that overruns the received data is rejected before it is read. Well-formed frames, whose packets are fully present, are unaffected.
Business impact
Successful exploitation of CVE-2026-64540, a reported vulnerability affecting the affected product, may affect the confidentiality, integrity or availability of the vulnerable environment. The exact impact depends on the installed version, exposed interfaces and deployment configuration.
Recommended administrator action
Confirm whether the affected product is present and compare installed versions with the vendor advisory and NVD record. Apply the vendor patch or documented mitigation; until remediation is complete, reduce exposure of affected interfaces, review relevant logs and monitor for indicators of exploitation. DataHouse can support version verification, managed patching, network exposure reduction, log review and backup validation for dedicated, cloud and colocated environments.