CVE-2026-64504

CVE-2026-64504: reported vulnerability affecting the affected product. Check CVSS, KEV status, business impact and recommended administrator actions.
CVE-2026-64504Linux

CVE-2026-64504

CVE-2026-64504: reported vulnerability affecting the affected product. Check CVSS, KEV status, business impact and recommended administrator actions.

CVSS
-
EPSS
6.12%
Known exploited
not in KEV
Product
-

What is known

In the Linux kernel, the following vulnerability has been resolved: iio: accel: bmc150: clamp the device-reported FIFO frame count __bmc150_accel_fifo_flush() copies the number of samples the device reports in its hardware FIFO into an on-stack buffer u16 buffer[BMC150_ACCEL_FIFO_LENGTH * 3]; which is sized for at most BMC150_ACCEL_FIFO_LENGTH (32) samples. The frame count is read from the FIFO_STATUS register and only masked to its 7 valid bits: count = val & 0x7F; so it can be 0..127. The only other limit applied to it is the optional caller-supplied sample budget: if (samples && count > samples) count = samples; which does not constrain count on the flush-all path (samples == 0), and leaves it well above 32 whenever samples is larger. count samples are then transferred into buffer[]: bmc150_accel_fifo_transfer(data, (u8 *)buffer, count); bmc150_accel_fifo_transfer() reads count * 6 bytes through regmap, so a malfunctioning, malicious or counterfeit accelerometer (or an attacker tampering with the I2C/SPI bus) that reports up to 127 frames writes up to 762 bytes into the 192-byte buffer: a stack out-of-bounds write of up to 570 bytes that clobbers the stack canary, saved registers and the return address. Clamp count to BMC150_ACCEL_FIFO_LENGTH, the number of samples buffer[] is sized for, before the transfer, mirroring the watermark clamp already done in bmc150_accel_set_watermark(). A well-formed flush reports at most BMC150_ACCEL_FIFO_LENGTH frames, so legitimate devices are unaffected.

Business impact

Successful exploitation of CVE-2026-64504, a reported vulnerability affecting the affected product, may affect the confidentiality, integrity or availability of the vulnerable environment. The exact impact depends on the installed version, exposed interfaces and deployment configuration.

Recommended administrator action

Confirm whether the affected product is present and compare installed versions with the vendor advisory and NVD record. Apply the vendor patch or documented mitigation; until remediation is complete, reduce exposure of affected interfaces, review relevant logs and monitor for indicators of exploitation. DataHouse can support version verification, managed patching, network exposure reduction, log review and backup validation for dedicated, cloud and colocated environments.

Sources

Security newsletter

Get new CVE alerts before they become an incident

We send selected infrastructure threats in English, with practical notes for DataHouse environments.

  • DataHouse: server administration and secure cloud
  • Hostilla.pl: hosting and mail services
  • SecDNS.pl: free DNS security layer