CVE-2026-64477

CVE-2026-64477: reported vulnerability affecting the affected product. Check CVSS, KEV status, business impact and recommended administrator actions.
CVE-2026-64477Linux

CVE-2026-64477

CVE-2026-64477: reported vulnerability affecting the affected product. Check CVSS, KEV status, business impact and recommended administrator actions.

CVSS
-
EPSS
7.37%
Known exploited
not in KEV
Product
-

What is known

In the Linux kernel, the following vulnerability has been resolved: x86,fs/resctrl: Prevent out-of-bounds access while offlining CPU when SNC enabled The architecture updates the cpu_mask in a domain's header to track which online CPUs are associated with the domain. When this mask becomes empty the architecture initiates offline of the domain that includes calling on resctrl fs to offline the domain. If it is a monitoring domain in which LLC occupancy is tracked resctrl fs forces the limbo handler to clear all busy RMID state associated with the domain. The limbo handler always reads the current event value associated with a busy RMID irrespective of it being checked as part of regular "is it still busy" check or whether it will be forced released anyway. When reading an RMID on a system with SNC enabled the "logical RMID" is converted to the "physical RMID" and this conversion requires the NUMA node ID of the resctrl monitoring domain that is in turn determined by querying the NUMA node ID of any CPU belonging to the monitoring domain. When the monitoring domain is going offline its cpu_mask is empty causing the NUMA node ID query via cpu_to_node() to be done with "nr_cpu_ids" as argument resulting in an out-of-bounds access. Refactor the limbo handler to skip reading the RMID when the RMID will just be forced to no longer be dirty in the domain anyway. Add a safety check to the architecture's RMID reader to protect against this scenario.

Business impact

Successful exploitation of CVE-2026-64477, a reported vulnerability affecting the affected product, may affect the confidentiality, integrity or availability of the vulnerable environment. The exact impact depends on the installed version, exposed interfaces and deployment configuration.

Recommended administrator action

Confirm whether the affected product is present and compare installed versions with the vendor advisory and NVD record. Apply the vendor patch or documented mitigation; until remediation is complete, reduce exposure of affected interfaces, review relevant logs and monitor for indicators of exploitation. DataHouse can support version verification, managed patching, network exposure reduction, log review and backup validation for dedicated, cloud and colocated environments.

Sources

Security newsletter

Get new CVE alerts before they become an incident

We send selected infrastructure threats in English, with practical notes for DataHouse environments.

  • DataHouse: server administration and secure cloud
  • Hostilla.pl: hosting and mail services
  • SecDNS.pl: free DNS security layer