What is known
In the Linux kernel, the following vulnerability has been resolved: usb: gadget: udc: Fix use-after-free in gadget_match_driver The udc structure acts as the management structure for the gadget, but their lifecycles are decoupled. A race condition exists where usb_del_gadget() frees the udc memory (e.g., via mode-switch work) while gadget_match_driver() concurrently accesses the freed udc memory (e.g., via configfs), causing a Use-After-Free (UAF) that triggers a NULL pointer dereference when the freed memory is zeroed: [39430.908615][ T1171] Unable to handle kernel NULL pointer dereference at virtual address 0000000000000000 [39430.911397][ T1171] pc : __pi_strcmp+0x20/0x140 [39430.911441][ T1171] lr : gadget_match_driver+0x34/0x60 ... [39430.911890][ T1171] usb_gadget_register_driver_owner+0x50/0xf8 [39430.911910][ T1171] gadget_dev_desc_UDC_store+0xf4/0x140 [39430.931308][ T1171] configfs_write_iter+0xec/0x134 [39430.957058][ T1171] Workqueue: events_freezable __dwc3_set_mode [39430.957287][ T1171] dwc3_gadget_exit+0x34/0x8c [39430.957304][ T1171] __dwc3_set_mode+0xc0/0x664 Fix this by ensuring the udc structure remains allocated until the gadget is released. To achieve this, introduce a new usb_gadget_release() routine to the core. When the gadget is added, usb_add_gadget() stores the gadget's release routine in the udc structure and takes a reference to the udc. When the gadget is released, usb_gadget_release() drops the reference to the udc and then calls the gadget's release routine.
Business impact
Successful exploitation of CVE-2026-64346, a reported vulnerability affecting the affected product, may affect the confidentiality, integrity or availability of the vulnerable environment. The exact impact depends on the installed version, exposed interfaces and deployment configuration.
Recommended administrator action
Confirm whether the affected product is present and compare installed versions with the vendor advisory and NVD record. Apply the vendor patch or documented mitigation; until remediation is complete, reduce exposure of affected interfaces, review relevant logs and monitor for indicators of exploitation. DataHouse can support version verification, managed patching, network exposure reduction, log review and backup validation for dedicated, cloud and colocated environments.