CVE-2026-64317

CVE-2026-64317: high vulnerability affecting the affected product. Check CVSS, KEV status, business impact and recommended administrator actions.
CVE-2026-64317CVSS 7.1Linux

CVE-2026-64317

CVE-2026-64317: high vulnerability affecting the affected product. Check CVSS, KEV status, business impact and recommended administrator actions.

CVSS
7.1 HIGH
EPSS
5.56%
Known exploited
not in KEV
Product
-

What is known

In the Linux kernel, the following vulnerability has been resolved: isofs: bound Rock Ridge symlink components to the SL record get_symlink_chunk() and the SL handling in parse_rock_ridge_inode_internal() walk the variable-length components of a Rock Ridge "SL" (symbolic link) record. Each component is a two-byte header (flags, len) followed by len bytes of text, so it occupies slp->len + 2 bytes. Both loops read slp->len and advance to the next component, and get_symlink_chunk() additionally does memcpy(rpnt, slp->text, slp->len), but neither checks that the component lies within the SL record before dereferencing it. A crafted SL record whose component declares a len that runs past the record (rr->len) therefore triggers an out-of-bounds read of up to 255 bytes. When the record sits at the tail of its backing buffer - for example a small kmalloc()ed continuation block reached through a CE record - the read crosses the allocation; get_symlink_chunk() then copies the out-of-bounds bytes into the symlink body returned to user space by readlink(), disclosing adjacent kernel memory. ISO 9660 images are routinely mounted from untrusted removable media - desktop environments auto-mount them (e.g. via udisks2) without CAP_SYS_ADMIN - so the record contents are attacker-controlled. Reject any component that does not fit in the remaining record bytes before using it. In get_symlink_chunk() return NULL, like the existing output-buffer (plimit) checks, so a malformed record makes readlink() fail with -EIO rather than silently returning a truncated target; in parse_rock_ridge_inode_internal() stop the inode-size walk.

Business impact

Successful exploitation of CVE-2026-64317, a high vulnerability (CVSS 7.1) affecting the affected product, may affect the confidentiality, integrity or availability of the vulnerable environment. The exact impact depends on the installed version, exposed interfaces and deployment configuration.

Recommended administrator action

Confirm whether the affected product is present and compare installed versions with the vendor advisory and NVD record. Apply the vendor patch or documented mitigation; until remediation is complete, reduce exposure of affected interfaces, review relevant logs and monitor for indicators of exploitation. DataHouse can support version verification, managed patching, network exposure reduction, log review and backup validation for dedicated, cloud and colocated environments.

Sources

Security newsletter

Get new CVE alerts before they become an incident

We send selected infrastructure threats in English, with practical notes for DataHouse environments.

  • DataHouse: server administration and secure cloud
  • Hostilla.pl: hosting and mail services
  • SecDNS.pl: free DNS security layer