CVE-2026-64250
CVE-2026-64250: reported vulnerability affecting the affected product. Check CVSS, KEV status, business impact and recommended administrator actions.
- CVSS
- -
- EPSS
- 5.72%
- Known exploited
- not in KEV
- Product
- -
What is known
In the Linux kernel, the following vulnerability has been resolved: LoongArch: Report dying CPU to RCU in stop_this_cpu() This is a port of MIPS commit 9f3f3bdc6d9dac1 ("MIPS: smp: report dying CPU to RCU in stop_this_cpu()"). smp_send_stop() parks all secondary CPUs in stop_this_cpu(). And the function marks the CPU offline for the scheduler via set_cpu_online(false) but never informs RCU, so RCU keeps expecting a quiescent state from CPUs that are now spinning forever with interrupts disabled. As long as nothing waits for an RCU grace period after smp_send_stop() this is harmless, which is why it went unnoticed. However, since commit 91840be8f710370 ("irq_work: Fix use-after-free in irq_work_single() on PREEMPT_RT"), irq_work_sync() calls synchronize_rcu() on architectures without an irq_work self-IPI, i.e. where arch_irq_work_has_interrupt() returns false. Any irq_work_sync() issued in the reboot/shutdown/halt path after smp_send_stop() then blocks on a grace period that can never complete, hanging the reboot: WARNING: CPU: 0 PID: 15 at kernel/irq_work.c:144 irq_work_queue_on ... rcu: INFO: rcu_sched detected stalls on CPUs/tasks: rcu: Offline CPU 1 blocking current GP. rcu: Offline CPU 2 blocking current GP. rcu: Offline CPU 3 blocking current GP. This issue needs some hacks to reproduce, and it was not noticed on LoongArch because arch_irq_work_has_interrupt() usually returns true. Call rcutree_report_cpu_dead() once interrupts are disabled, mirroring the generic CPU-hotplug offline path, so RCU stops waiting on the parked CPUs and grace periods can still complete. LoongArch shuts down all CPUs here without going through the CPU-hotplug mechanism, so this report is not otherwise issued.
Business impact
Successful exploitation of CVE-2026-64250, a reported vulnerability affecting the affected product, may affect the confidentiality, integrity or availability of the vulnerable environment. The exact impact depends on the installed version, exposed interfaces and deployment configuration.
Recommended administrator action
Confirm whether the affected product is present and compare installed versions with the vendor advisory and NVD record. Apply the vendor patch or documented mitigation; until remediation is complete, reduce exposure of affected interfaces, review relevant logs and monitor for indicators of exploitation. DataHouse can support version verification, managed patching, network exposure reduction, log review and backup validation for dedicated, cloud and colocated environments.