CVE-2026-64192
CVE-2026-64192: reported vulnerability affecting the affected product. Check CVSS, KEV status, business impact and recommended administrator actions.
- CVSS
- -
- EPSS
- 5.83%
- Known exploited
- not in KEV
- Product
- -
What is known
In the Linux kernel, the following vulnerability has been resolved: bpf: Reject BPF_MAP_TYPE_INODE_STORAGE creation if BPF LSM is uninitialized When CONFIG_BPF_LSM=y is set, BPF inode storage maps (BPF_MAP_TYPE_INODE_STORAGE) are compiled into the kernel. However, if the BPF LSM is not explicitly enabled at boot time (e.g. omitted from the "lsm=" boot parameter), lsm_prepare() is never executed for the BPF LSM. Consequently, the BPF inode security blob offset (bpf_lsm_blob_sizes.lbs_inode) is never initialized and remains at its default compiled size of 8 bytes instead of being updated to a valid offset past the reserved struct rcu_head (typically 16 bytes or more). When a privileged user creates and updates a BPF_MAP_TYPE_INODE_STORAGE map, bpf_inode() evaluates inode->i_security + 8. This erroneously aliases the struct rcu_head.func callback pointer at the beginning of the inode->i_security blob. During subsequent map element cleanup or inode destruction, writing NULL to owner_storage clears the queued RCU callback pointer. When rcu_do_batch() later executes the queued callback, it attempts an instruction fetch at address 0x0, triggering an immediate kernel panic. Fix this by introducing a global bpf_lsm_initialized boolean flag marked with __ro_after_init. Set this flag to true inside bpf_lsm_init() when the LSM framework successfully registers the BPF LSM. Gate map allocation in inode_storage_map_alloc() on this flag, returning -EOPNOTSUPP if the BPF LSM is in turn uninitialized. This fail-fast approach prevents userspace from allocating inode storage maps when the supporting BPF LSM infrastructure is absent, avoiding zombie map states.
Business impact
Successful exploitation of CVE-2026-64192, a reported vulnerability affecting the affected product, may affect the confidentiality, integrity or availability of the vulnerable environment. The exact impact depends on the installed version, exposed interfaces and deployment configuration.
Recommended administrator action
Confirm whether the affected product is present and compare installed versions with the vendor advisory and NVD record. Apply the vendor patch or documented mitigation; until remediation is complete, reduce exposure of affected interfaces, review relevant logs and monitor for indicators of exploitation. DataHouse can support version verification, managed patching, network exposure reduction, log review and backup validation for dedicated, cloud and colocated environments.