CVE-2023-53800

CVE-2023-53800: reported vulnerability affecting the affected product. Check CVSS, KEV status, business impact and recommended administrator actions.
CVE-2023-53800Linux

CVE-2023-53800

CVE-2023-53800: reported vulnerability affecting the affected product. Check CVSS, KEV status, business impact and recommended administrator actions.

CVSS
-
EPSS
7.24%
Known exploited
not in KEV
Product
-

What is known

In the Linux kernel, the following vulnerability has been resolved: ubi: Fix use-after-free when volume resizing failed There is an use-after-free problem reported by KASAN: ================================================================== BUG: KASAN: use-after-free in ubi_eba_copy_table+0x11f/0x1c0 [ubi] Read of size 8 at addr ffff888101eec008 by task ubirsvol/4735 CPU: 2 PID: 4735 Comm: ubirsvol Not tainted 6.1.0-rc1-00003-g84fa3304a7fc-dirty #14 Hardware name: QEMU Standard PC (i440FX + PIIX, 1996), BIOS 1.14.0-1.fc33 04/01/2014 Call Trace: <TASK> dump_stack_lvl+0x34/0x44 print_report+0x171/0x472 kasan_report+0xad/0x130 ubi_eba_copy_table+0x11f/0x1c0 [ubi] ubi_resize_volume+0x4f9/0xbc0 [ubi] ubi_cdev_ioctl+0x701/0x1850 [ubi] __x64_sys_ioctl+0x11d/0x170 do_syscall_64+0x35/0x80 entry_SYSCALL_64_after_hwframe+0x46/0xb0 </TASK> When ubi_change_vtbl_record() returns an error in ubi_resize_volume(), "new_eba_tbl" will be freed on error handing path, but it is holded by "vol->eba_tbl" in ubi_eba_replace_table(). It means that the liftcycle of "vol->eba_tbl" and "vol" are different, so when resizing volume in next time, it causing an use-after-free fault. Fix it by not freeing "new_eba_tbl" after it replaced in ubi_eba_replace_table(), while will be freed in next volume resizing.

Business impact

Successful exploitation of CVE-2023-53800, a reported vulnerability affecting the affected product, may affect the confidentiality, integrity or availability of the vulnerable environment. The exact impact depends on the installed version, exposed interfaces and deployment configuration.

Recommended administrator action

Confirm whether the affected product is present and compare installed versions with the vendor advisory and NVD record. Apply the vendor patch or documented mitigation; until remediation is complete, reduce exposure of affected interfaces, review relevant logs and monitor for indicators of exploitation. DataHouse can support version verification, managed patching, network exposure reduction, log review and backup validation for dedicated, cloud and colocated environments.

Sources

Security newsletter

Get new CVE alerts before they become an incident

We send selected infrastructure threats in English, with practical notes for DataHouse environments.

  • DataHouse: server administration and secure cloud
  • Hostilla.pl: hosting and mail services
  • SecDNS.pl: free DNS security layer